Our Research

A matrix of scientific key strengths defines four main themes for advanced imaging research and innovation at ICE.

Scientific Research Strengths

Fundamental 7T neuroimaging research

Theme 1: Information processing in the brain circuits that realise perception, prediction, memory, cognition control and decision making

Using measurement technologies that span multiple levels of brain activity to study cortical networks, computational principles, and microcircuits for cognition.

Research Leads

Surface reconstruction of human visual cortex overlaid with grid lines depicting cortical depths from superficial (red) to deep (purple) layers, from which task-related activity was acquired using high-field, high-resolution fMRI at 7 Tesla.

Surface reconstruction of human visual cortex overlaid with grid lines depicting cortical depths from superficial (red) to deep (purple) layers. Using high-field, high-resolution fMRI at 7 Tesla, Prof Lars Muckli’s group showed for the first time that the brain’s internal representations of the world are fed back to superficial layers of sensory cortex.

Clinical 7T neuroimaging research

Theme 2: Neurobiology of response to disease mechanism and injury

A programme of interdisciplinary, translational research focussed on the neurobiological mechanisms of behavioural phenotypes such as depression, fatigue and chronic pain resulting from injury to the nervous system and inflammation.

Research Leads

MR Physics and RF Coil Engineering

Theme 3: Development of coils and parallel transmit imaging capabilities

Development of novel radiofrequency (RF) coils and parallel-transmit (pTx) technology is essential to fully exploit the capabilities of ultra-high field 7T MRI.

Research Leads

Comparison of Glasgow 8Tx/32Rx coil to Nova Coil

A novel 7T head coil developed in house at ICE and badged as the 'Glasgow Coil' provides improved whole-brain coverage (lower right) in contrast to the current commercial option (lower left). Additional advantages of the Glasgow Coil are its open-faced design to reduce claustrophobia and allow subject monitoring, and its dual-mode functionality to support imaging in single-transmit, sTx mode (currently used for clinical diagnosis) and parallel-transmit, pTx mode (currently used for research and clinical validation) in a single device.

Extending 7T imaging diagnostics

Theme 4: Extending capability of diagnostics across the human body

Extending imaging diagnostics allowing for NHS applications, industrial collaborations, and with potential for developing impact cases. Clinical research across imaging techniques including clinical radiology, cardiovascular, tumour and stroke imaging.

Research Leads

Research Publications

2025

Gapais, P.‐F., Luong, M., Giacomini, E., Guillot, J., Djaballah, E., Gunamony, S., Chu, S., Hosseinnezhadian, S., Amadon, A. (2025) A 32‐channel high‐impedance honeycomb‐shaped receive array for temporal lobes exploration at 11.7T. Magnetic Resonance in Medicine, 93, pp. 433-447. (doi: 10.1002/mrm.30274)

2024

Ding, B., Williams, S. N., Dragonu, I., Liebig, P., Allwood-Spiers, S., McElhinney, P., Gunamony, S., Fullerton, N., Porter, D. A. (2024) Slice-specific B1+ shimming improves the repeatability of multi-shot, diffusion-weighted imaging at 7T. Magnetic Resonance in Medicine, 92, pp. 2560-2570. (doi: 10.1002/mrm.30208)

Boulant, N., Ma, S., Walker, E., Beckett, A., Vu, A. T., Gunamony, S., Feinberg, D. A. (2024) Acoustic noise reduction in the NexGen 7 T scanner. Magnetic Resonance in Medicine, 92, pp. 2261-2270. (doi: 10.1002/mrm.30211)

Winata, S., Hoinkiss, D. C., Keith, G., Williams, S., Ding, B., Al-Wasity, S., Gunamony, S., Porter, D. (2024) Real-time multislice-to-volume motion correction with single and parallel transmission for task-based functional MRI at 7T.

Gokyar, S., Zhao, C., Gunamony, S., Tang, L., West, J., Kokot, N., Wang, D. J. J. (2024) A 3D surface coil with deep learning‐based noise reduction for parotid gland imaging at 7T. iRadiology, 2, pp. 368-376. (doi: 10.1002/ird3.79)

Keith, G. A., Woodward, R. A., Hopkins, T., Allwood-Spiers, S., Trinder, J., Muir, K., Porter, D. A., Fullerton, N. E. (2024) Towards clinical translation of 7 Tesla MRI in the human brain. IPEM-Translation, 9, (doi: 10.1016/j.ipemt.2024.100025)

Baskaran, D., McElhinney, P., Williams, S., Allwood-Spiers, S., Ding, B., Fullerton, N., Porter, D., Gunamony, S. (2024) An 8-channel Transceiver and 56-channel Receive Array for Combined Brain and C-spine Imaging at 7 Tesla.

Keith, G., Williams, S., Ding, B., Trinder, J., Seginer, A., Schmidt, R., Gunamony, S., Fullerton, N., Porter, D. (2024) B1+ Shimming in 1H RS-COKE Spectroscopic Imaging in the Human Brain at 7T.

Ding, B., Yan, J., Woodward, R., Allwood-Spiers, S., Williams, S., Keith, G., McElhinney, P., Fullerton, N., Porter, D., Gunamony, S. (2024) Combining Transceiver Loops with a Conventional Receive Array Increases Central SNR in Brain Imaging at 7T.

Ghosalkar, J., Ding, B., Zhao, C., Keith, G., Baskaran, D., Woodward, R., Ma, S., Williams, S., Muir, K., Gunamony, S., Wang, D. J.J., Porter, D. (2024) Initial Experience in pCASL Using a Novel Neurovascular Coil at 7T.

Winata, S., Hoinkiss, D., Keith, G., Williams, S., Ding, B., Al-Wasity, S., Porter, D. (2024) Real-time Multislice-to-volume Motion Correction with B1+ Shimming for Task-based Functional MRI at 7T.

Wu, W. et al. (2024) High resolution diffusion imaging in the unfixed post-mortem infant brain at 7T. Imaging Neuroscience, (doi: 10.1162/imag_a_00069)

2023

Winata, S., Hoinkiss, D.C., Keith, G.A., Williams, S.N., Ding, B.Y., Al-Wasity, S., Gunamony, S., Porter, D.A. (2023) Parallel Transmit Imaging with Real-time Multislice-to-volume Motion Correction for Task-based Functional MRI at 7T.

Winata, S., Hoinkiss, D.C., Keith, G.A., Al-Wasity, S., Porter, D.A. (2023) Real-time Multislice-to-volume Motion Correction for Task-based Functional MRI at 7T.

Chu, S., Gras, V., Mauconduit, F., Massire, A., Boulant, N., Gunamony, S. (2023) Electromagnetic and RF pulse design simulation based optimization of an eight-channel loop array for 11.7T brain imaging. Magnetic Resonance in Medicine, 90, pp. 770-783. (doi: 10.1002/mrm.29654)

Winata, S., Hoinkiss, D. C., Keith, G., Al-Wasity, S., Porter, D. (2023) Prospective Motion Correction for Functional MRI at 7T using Multislice-to-Volume Image Registration.

Winata, S., Hoinkiss, D., Keith, G., Al-Wasity, S., Porter, D. (2023) Real-time Image-based Motion Correction for 7T Task-based Functional MRI.

Winata, S., Hoinkiss, D. C., Keith, G. A., Al-Wasity, S. M., Porter, D. A. (2023) Multislice-to-Volume Prospective Motion Correction for Functional MRI Protocols at 7T.

Baskaran, D., McElhinney, P., Williams, S., Allwood-Spiers, S., Porter, D., Gunamony, S. (2023) Eight-channel Transceiver Array for Combined Head and Neck Imaging at 7 Tesla.

Williams, S., McElhinney, P., Ding, B., Allwood-Spiers, S., Porter, D., Gunamony, S., Brink, W. (2023) Experimental Assessment of the Effects of Subject Motion on Local SAR and pTx Pulse Performance at 7T.

Ding, B., Williams, S., Zhang, M., Herrler, J., Liebig, P., Dragonu, I., Neji, R., Rodgers, C., Porter, D. (2023) Optimisation of Pulse-specific Phase Schedules Reduces Peak RF Amplitude in Multiband Parallel-transmit Pulses.

Ding, B., Williams, S., Dragonu, I., Herrler, J., Allwood-Spiers, S., Liebig, P., Porter, D. (2023) Slice-specific B1 Shimming Can Improve the Repeatability of Multi-shot, Diffusion-weighted Imaging at 7T.

Baskaran, D., McElhinney, P., Williams, S., Allwood-Spiers, S., Porter, D., Gunamony, S. (2023) Eight-channel Transceiver and Fifty-six Channel Receiver Array for Combined Head-and-neck Imaging at 7 Tesla.

Ding, B., Ghosalkar, J., Williams, S., Forbes, K., Woodward, R., Dragonu, I., Porter, D., Muir, K., Foo, S. Y. (2023) Vessel Wall Imaging at 7 Tesla Using 3D Turbo Spin-echo.

Herrler, J., Williams, S. N., Liebig, P., Ding, B., McElhinney, P., Allwood-Spiers, S., Meixner, C. R., Gunamony, S., Maier, A., Dörfler, A., Gumbrecht, R., Porter, D. A., Nagel, A. M. (2023) The effects of RF coils and SAR supervision strategies for clinically applicable nonselective parallel-transmit pulses at 7 T. Magnetic Resonance in Medicine, 89, pp. 1888-1900. (doi: 10.1002/mrm.29569)

Williams, S. N., McElhinney, P., Gunamony, S. (2023) Ultra-high field MRI: parallel-transmit arrays and RF pulse design. Physics in Medicine and Biology, 68, (doi: 10.1088/1361-6560/aca4b7)

2022

Seginer, A., Keith, G. A., Porter, D. A., Schmidt, R. (2022) Artifact suppression in readout‐segmented consistent K‐t space EPSI (RS‐COKE) for fast 1 H spectroscopic imaging at 7 T. Magnetic Resonance in Medicine, 88, pp. 2339-2357. (doi: 10.1002/mrm.29373)

Winata, S., Hoinkiss, D. C., Keith, G., Porter, D. (2022) Multislice-to-Volume Registration for Detecting Intra-Volume Motion in 7T EPI.

Williams, S. N., Ding, B., Dragonu, I., Liebig, P., Porter, D. A. (2022) First Evaluation of External Development Sequences for 7 T Parallel-Transmit MRI in a Self-Built RF Coil.

Breutigam, N.-J., Günther, M., Hoinkiss, D. C., Eickel, K., Frost, R., Buck, M. A., Porter, D. A. (2022) Combined acquisition of diffusion and T2*-weighted measurements using simultaneous multi-contrast magnetic resonance imaging. Magnetic Resonance Materials in Physics, Biology and Medicine, 35, pp. 421-440. (doi: 10.1007/s10334-021-00976-3)

Williams, S., Dragonu, I., Ding, B., Liebig, P., Porter, D. (2022) Parallel Transmission for Improved Multishot Diffusion Weighted Imaging at 7T.

Seginer, A., Keith, G. A., Porter, D. A., Schmidt, R. (2022) Reducing Artifacts in Readout-Segmented Spectroscopic Imaging at 7T.

Liebig, P., Herrler, J., Tomi-Tricot, R., Williams, S., Ding-Yuan, B., Hlou, M., Chebrolu, V., Gadjimuradov, F., Hilbert, T., Kober, T., Gumbrecht, R., Heidemann, R. M., Benkert, T., Rodgers, C., Porter, D. A., Dragonu, I., Nagel, A., Malik, S. (2022) Generalized Framework for Homogeneous Ultra-High-Field Brain Imaging.

Williams, S. N., Dragonu, I., Ding, B., Liebig, P., Porter, D. A. (2022) Simultaneous Multislice pTx for Readout-Segmented Diffusion Imaging at 7 T.

Ding, B., Williams, S. N., Dragonu, I., Liebig, P., Porter, D. A. (2022) Parallel transmission for 7T multi-shot diffusion-weighted imaging.

2021

Winata, S., Hoinkiss, D.C., Keith, G. A., Porter, D. A., Gunther, M. (2021) Navigator Parameter Optimisation for MS-PACE Prospective Motion Correction.

Winata, S., Hoinkiss, D.C., Keith, G. A., Porter, D. A., Gunther, M. (2021) Optimising Navigator Scans for Use in MRI Prospective Motion Correction.

Winata, S., Hoinkiss, D.C., Keith, G. A., Porter, D. A., Gunther, M. (2021) Image Registration Shortcut for Prospective Motion Correction Using Unseparated Multiband Slices. (doi: 10.1007/s10334-021-00947-8)

Williams, S. N., Allwood-Spiers, S., McElhinney, P., Paterson, G., Herrler, J., Liebig, P., Nagel, A. M., Foster, J. E., Porter, D. A., Gunamony, S. (2021) A nested eight-channel transmit array with open-face concept for human brain imaging at 7 tesla. Frontiers in Physics, 9, (doi: 10.3389/fphy.2021.701330)

Keith, G., Seginer, A., Porter, D., Schmidt, R. (2021) Echo-planar Spectroscopic Imaging with Readout-segmented COKE at 7T: Artifact Analysis using a Purpose-Built Phantom and Simulation.

Gunamony, S., Müller, R., McElhinney, P., Williams, S., Groß-Weege, N., Weiskopf, N., Möller, H. E., Feinberg, D. (2021) A 16-Channel Transmit 96-Channel Receive Head Coil for NexGen 7T Scanner.

Herrler, J., Williams, S., Liebig, P., Gunamony, S., Meixner, C., Maier, A., Dörfler, A., Porter, D., Nagel, A. M. (2021) Evaluating Universal and Fast Online Customized Pulses for Parallel Transmission Using Two Different RF Coils.

Winata, S., Hoinkiss, D.C., Keith, G. A., Porter, D. A., Gunther, M. (2021) Optimisation of Navigator Parameter for MS-PACE Prospective Motion Correction.

McElhinney, P., Paterson, G., Philiastides, M., Gunamony, S. (2021) Numerical Modelling of a Close-fitting 8-channel Transceiver Head Coil and EEG Electrodes for Safety Validation at 7T.

Williams, S.N., Dragonu, I., Liebig, P., Porter, D.A. (2021) Multi-Slice 2D pTx Readout-Segmented Diffusion-Weighted Imaging Using Slice-by-Slice B1+ Shimming.

Williams, S. N., Herrler, J., Liebig, P., McElhinney, P., Gunamony, S., Nagel, A. M., Porter, D. A. (2021) SAR Management in pTx Sequence Design: The Impact of Electromagnetic-Field-Derived Virtual Observation Points.

Williams, S. N., Allwood-Spiers, S., McElhinney, P., Tao, Y., Foster, J. E., Gunamony, S., Porter, D. A. (2021) Validation of SAR Management Procedure for Dynamic pTx RF Waveforms Using a Self- Built Coil at 7 Tesla.

Williams, S. N., Herrler, J., Liebig, P., McElhinney, P., Allwood-Spiers, S., Foster, J. E., Gunamony, S., Nagel, A. M., Porter, D. A. (2021) Comparing Specific Absorption Rate (Tissue Heating) Management Methods for Parallel Transmit MRI at 7 Tesla.

2020

Williams, S. N., McElhinney, P., Porter, D., Gunamony, S. (2020) Comparing the Practical Effects of VOP Compressions for SAR Monitoring at 7 T.

Keith, G. (2020) Readout-Segmented COKE: A Technique for Echo-Planar Spectroscopic Imaging at 7 Tesla with High Spectral Bandwidth and Suppression of Nyquist Errors in the Spectral Domain.

Williams, S., Allwood-Spiers, S., McElhinney, P., Tao, Y., Foster, J. E., Porter, D. A., Gunamony, S. (2020) Validation and Safety Approval of a Dual-Mode Head Coil for pTx Applications In Vivo at 7 Tesla.

Liebig, P. A., Heidemann, R. M., Hensel, B., Porter, D. A. (2020) A new approach to accelerate readout segmented EPI with compressed sensing. Magnetic Resonance in Medicine, 84, pp. 321-326. (doi: 10.1002/mrm.28116)

Williams, S. N., Allwood-Spiers, S., McElhinney, P., Tao, Y., Foster, J., Porter, D., Gunamony, S. (2020) First In Vivo Images from an InHouse Parallel Transmit (pTx) Coil for MRI at 7 Tesla.

Cordes, C., Konstandin, S., Porter, D., Günther, M. (2020) Portable and platform‐independent MR pulse sequence programs. Magnetic Resonance in Medicine, 83, pp. 1277-1290. (doi: 10.1002/mrm.28020)

2019

Hoinkiss, D. C., Erhard, P., Breutigam, N.-J., von Samson-Himmelstjerna, F., Günther, M., Porter, D. A. (2019) Prospective motion correction in functional MRI using simultaneous multislice imaging and multislice-to-volume image registration. NeuroImage, 200, pp. 159-173. (doi: 10.1016/j.neuroimage.2019.06.042)

McElhinney, P., Allwood-Spiers, S., Gunamony, S. (2019) Computational Simulation of an 8Tx32Rx Open-face Head Coil for 7 Tesla.

Gunamony, S., McElhinney, P., Allwood-Spiers, S., Paterson, G., Goense, J. (2019) An 8-Channel Transmit 32-Channel Receive 7T Head Coil for 1Tx and pTx Scanner Modes.

Keith, G., Vicari, M., Woodward, R., Porter, D. (2019) In Vivo Echo-Planar Spectroscopic Imaging (EPSI) at 7 Tesla with Readout Segmentation for Improved Spectral Bandwidth.

Avdievich, N. I., Giapitzakis, I.‐A., Bause, J., Shajan, G., Scheffler, K., Henning, A. (2019) Double‐row 18‐loop transceive–32‐loop receive tight‐fit array provides for whole‐brain coverage, high transmit performance, and SNR improvement near the brain center at 9.4T. Magnetic Resonance in Medicine, 81, pp. 3392-3405. (doi: 10.1002/mrm.27602)

Keith, G. (2019) Imaging at ultra-high field: a new era in clinical MRI? European Medical Physics News, 2019, pp. 25-28.

Liebig, P., Heidemann, R. M., Hensel, B., Porter, D. A. (2019) Accelerated silent echo-planar imaging. Magnetic Resonance Imaging, 55, pp. 81-85. (doi: 10.1016/j.mri.2018.09.016)

Gunamony, S., Hoffmann, J., Scheffler, K., Pohmann, R. (2019) Transmit/receive switch, a transmit coil array and a receive coil array for MRI.

Adriany, G., Radder, J., Tavaf, N., Lagore, R., Jungst, S., Woo, M. K., Grant, A., Eryaman, Y., Zhang, B., Gundamony, S., Lattanzi, R., Ugurbil, K., van de Moortele, P.- F. (2019) Evaluation of a 16-Channel Transmitter for Head Imaging at 10.5T. (doi: 10.1109/ICEAA.2019.8879131)

2018

Avdievich, N. I., Giapitzakis, I. A., Pfrommer, A., Shajan, G., Scheffler, K., Jemmomg, A. (2018) Decoupling of a double‐row 16‐element tight‐fit transceiver phased array for human whole‐brain imaging at 9.4T. NMR in Biomedicine, 31, (doi: 10.1002/nbm.3964)

Eickel, K., Porter, D. A., Söhner, A., Maaß, M., Lüdemann, L., Günther, M. (2018) Simultaneous multislice acquisition with multi-contrast segmented EPI for separation of signal contributions in dynamic contrast-enhanced imaging. PLoS ONE, 13, (doi: 10.1371/journal.pone.0202673)

2017

Hoinkiss, D. C., Porter, D. A. (2017) Prospective motion correction in 2D multishot MRI using EPI navigators and multislice-to-volume image registration. Magnetic Resonance in Medicine, 78, pp. 2127-2135. (doi: 10.1002/mrm.26951)

Kozlov, M., Bode, J., Bazin, P.-L., Weiskopf, N., Moller, H.E., Gunamony, S. (2017) Comparison of 7T 16-channel Dual-row Transmit Arrays. (doi: 10.1109/ICEAA.2017.8065502)

Algin, O., Aydın, H., Ozmen, E., Ocakoglu, G., Bercin, S., Porter, D.A., Kutluhan, A. (2017) Detection of cholesteatoma: High-resolution DWI using RS-EPI and parallel imaging at 3 tesla. Journal of Neuroradiology, 44, pp. 388-394. (doi: 10.1016/j.neurad.2017.05.006)

Chadzynski, G. L., Bause, J., Shajan, G., Pohmann, R., Scheffler, K., Ehses, P. (2017) Fast and efficient free induction decay MR spectroscopic imaging of the human brain at 9.4 Tesla. Magnetic Resonance in Medicine, 78, pp. 1281-1295. (doi: 10.1002/mrm.26539)

Keith, G. A., Rodgers, C. T., Chappell, M. A., Robson, M. D. (2017) A look-locker acquisition scheme for quantitative myocardial perfusion imaging with FAIR arterial spin labeling in humans at 3 tesla. Magnetic Resonance in Medicine, 78, pp. 541-549. (doi: 10.1002/mrm.26388)

Hoinkiss, D. C., Porter, D. A. (2017) Prospective motion correction in diffusion-weighted imaging using intermediate pseudo-trace-weighted images. NeuroImage, 149, pp. 1-14. (doi: 10.1016/j.neuroimage.2016.12.055)

Avdievich, N.I., Hoffmann, J., Shajan, G., Pfrommer, A., Giapitzakis, I.A., Scheffler, K., Henning, A. (2017) Evaluation of transmit efficiency and SAR for a tight fit transceiver human head phased array at 9.4 T. NMR in Biomedicine, 30, (doi: 10.1002/nbm.3680)

Hagberg, G.E., Bause, J., Ethofer, T., Ehses, P., Dresler, T., Herbert, C., Pohmann, R., Shajan, G., Fallgatter, A., Pavlova, M.A., Scheffler, K. (2017) Whole brain MP2RAGE-based mapping of the longitudinal relaxation time at 9.4T. NeuroImage, 144, pp. 203-216. (doi: 10.1016/j.neuroimage.2016.09.047)

2016

Schaafs, L.-A., Porter, D., Audebert, H. J., Fiebach, J. B., Villringer, K. (2016) Optimising MR perfusion imaging: comparison of different software-based approaches in acute ischaemic stroke. European Radiology, 26, pp. 4204-4212. (doi: 10.1007/s00330-016-4244-3)

Hayes, L. L., Alazraki, A., Wasilewski-Masker, K., Jones, R. A., Porter, D. A., Palasis, S. (2016) Diffusion-weighted imaging using readout-segmented EPI reveals Bony metastases from neuroblastoma. Journal of Pediatric Hematology/Oncology, 38, pp. e263-e266. (doi: 10.1097/MPH.0000000000000643)

Bisdas, S., Chadzynski, G. L., Braun, C., Schittenhelm, J., Skardelly, M., Hagberg, G. E., Ethofer, T., Pohmann, R., Shajan, G., Engelmann, J., Tabatabai, G., Ziemann, U., Ernemann, U., Scheffler, K. (2016) MR spectroscopy for in vivo assessment of the oncometabolite 2-hydroxyglutarate and its effects on cellular metabolism in human brain gliomas at 9.4T. Journal of Magnetic Resonance Imaging, 44, pp. 823-833. (doi: 10.1002/jmri.25221)

Hoffmann, J., Henning, A., Giapitzakis, I. A., Scheffler, K., Shajan, G., Pohmann, R., Avdievich, N. I. (2016) Safety testing and operational procedures for self-developed radiofrequency coils. NMR in Biomedicine, 29, pp. 1131-1144. (doi: 10.1002/nbm.3290)

Jang, J., Ahn, K.-J., Kim, B.-Y., Porter, D., Stemmer, A., Choi, H. S., Jung, S.-L., Kim, B.-S. (2016) The usefulness of diffusion-weighted readout-segmented EPI and fast spin echo with BLADE (PROPELLER) k-space sampling: a comparison with single-shot EPI for diffusion-weighted imaging in ischemic stroke patients. International Journal of Imaging Systems and Technology, 26, pp. 216-224. (doi: 10.1002/ima.22179)

Kida, I., Ueguchi, T., Matsuoka, Y., Zhou, K., Stemmer, A., Porter, D. (2016) Comparison of diffusion-weighted imaging in the human brain using readout-segmented EPI and PROPELLER turbo spin echo with single-shot EPI at 7 T MRI. Investigative Radiology, 51, pp. 435-439. (doi: 10.1097/RLI.0000000000000248)

Mirkes, C., Shajan, G., Chadzynski, G., Buckenmaier, K., Bender, B., Scheffler, K. (2016) 31P CSI of the human brain in healthy subjects and tumor patients at 9.4 T with a three-layered multi-nuclear coil: initial results. Magnetic Resonance Materials in Physics, Biology and Medicine, 29, pp. 579-589. (doi: 10.1007/s10334-016-0524-9)

Yamada, H., Yamamoto, A., Okada, T., Kanagaki, M., Fushimi, Y., Porter, D. A., Tanji, M., Hojo, M., Miyamoto, S., Togashi, K. (2016) Diffusion tensor imaging of the optic chiasm in patients with intra- or parasellar tumor using readout-segmented echo-planar. Magnetic Resonance Imaging, 34, pp. 654-661. (doi: 10.1016/j.mri.2016.01.002)

Tse, D. H. Y., Wiggins, C. J., Ivanov, D., Brenner, D., Hoffmann, J., Mirkes, C., Shajan, G., Scheffler, K., Uludağ, K., Poser, B. A. (2016) Volumetric imaging with homogenised excitation and static field at 9.4 T. Magnetic Resonance Materials in Physics, Biology and Medicine, 29, pp. 333-345. (doi: 10.1007/s10334-016-0543-6)

Keith, G., Rodgers, C., Chappell, M., Robson, M. (2016) Reproducibility and Variability of a Look-Locker FAIR ASL Sequence for Quantitative Measurement of Myocardial Blood Flow in Healthy Human Volunteers at 3T.

Wiesner, H. M., Balla, D. Z., Shajan, G., Scheffler, K., Uğurbil, K., Chen, W., Uludağ, K., Pohmann, R. (2016) 17O relaxation times in the rat brain at 16.4 tesla. Magnetic Resonance in Medicine, 75, pp. 1886-1893. (doi: 10.1002/mrm.25814)

Bause, J., Ehses, P., Mirkes, C., Shajan, G., Scheffler, K., Pohmann, R. (2016) Quantitative and functional pulsed arterial spin labeling in the human brain at 9.4 t. Magnetic Resonance in Medicine, 75, pp. 1054-1063. (doi: 10.1002/mrm.25671)

Mirkes, C., Shajan, G., Bause, J., Buckenmaier, K., Hoffmann, J., Scheffler, K. (2016) Triple-quantum-filtered sodium imaging at 9.4 Tesla. Magnetic Resonance in Medicine, 75, pp. 1278-1289. (doi: 10.1002/mrm.25688)

Shajan, G., Mirkes, C., Buckenmaier, K., Hoffmann, J., Pohmann, R., Scheffler, K. (2016) Three-layered radio frequency coil arrangement for sodium MRI of the human brain at 9.4 Tesla. Magnetic Resonance in Medicine, 75, pp. 906-916. (doi: 10.1002/mrm.25666)

Hoffmann, J., Mirkes, C., Shajan, G., Scheffler, K., Pohmann, R. (2016) Combination of a multimode antenna and TIAMO for traveling-wave imaging at 9.4 Tesla. Magnetic Resonance in Medicine, 75, pp. 452-462. (doi: 10.1002/mrm.25614)